How can we help?
Choose a topic to get started.
-
Putting it together
Read here
-
What each button does
Read here
-
The three that solve most calls
Read here
-
Cleaning the glass
Read here
Setup and use
-
What is in the box
-
Putting it together
-
What each button does
-
Setting the temperature, and cycling the colours
-
The remote
-
Where it can stand
-
The numbers
Cleaning and care
-
Cleaning the glass
-
The warranty
Fix a problem
-
The three that solve most calls
-
Troubleshooting
-
Control panel does nothing
CauseThe power switch on the panel is off, or the data cable was left out after the glass frame came off
SolutionSwitch it on, and put the data cable back
-
Power cut out while it was heating
CauseThe air outlet is covered
SolutionClear it. Unplug, wait 15 minutes, try again
-
No hot air at switch-on or switch-off
CauseThe fan runs cool before and after heating
SolutionNormal, nothing to do
-
Heater will not turn on
CauseNo power, a tripped breaker from too many appliances on the circuit, unplugged, a damaged cord or plug, a loose outlet, or loose wiring
SolutionCheck the outlet and the breaker. It needs a 15 amp 120V AC grounded outlet. Loose wiring or a damaged cord needs us
-
On, but no flame or a weak flame
CauseSleep mode, or the flame is set low
SolutionHold DIMMER for 6 seconds, or raise the flame. If neither works it is loose wiring and needs us
-
The flame is frozen
CauseThe flame element is not attached to the motor, or the rotation motor has failed
SolutionBoth need us
-
Noise from the lower part
CauseThe flame element is not seated properly, or a motor has failed
SolutionContact us
-
Heat does not come on
CauseThe heat switch is off, or it has overheated because it is covered or the air path is blocked
SolutionClear the air path, switch off, unplug and wait 15 minutes. If it carries on it is loose wiring or a blocked inlet and needs us
-
HEAT pressed, no airflow
CauseThe overheat cut-out has tripped
SolutionCheck the inlet and outlet, unplug, wait 15 minutes. Both POWER and HEAT have to be on. A failed or unbalanced blower needs us
-
Fan runs but there is no heat
CauseLoose wiring, a bad heating element, dirt on the fans, or a failed fan
SolutionClean the fans. The rest needs us
-
The remote does nothing
CauseThe battery is in the wrong way round, the clear strip is still in, it is not aimed at the receiver, something is in the way, or the buttons were pressed too fast
SolutionPull the strip out, check the batteries, aim at the front and press slowly
-
A smell the first time it heats
CauseNormal on first heating
SolutionIt does not come back
-
Specs and what is in the box
SpecificationsOpenClose
A vintage-style heater with multi-angle flame views and strong steel build.
| Width | 23.5 inch |
|---|---|
| Depth | 10.7 inch |
| Height | 24.3 inch |
| Weight | 33.2 lbs |
| Heat Output | 5,100 BTU |
| Voltage | 120 VAC |
| Modes | 500 W and 1500 W |
In the boxOpenClose
| Electric Fireplace | x1 |
|---|---|
| Manual | x1 |
| Remote Control (Batteries included) | x1 |
| Legs | x4 |
| M5 Screws | x12 |
Register your product
Setup videos, manuals and support for your exact model.